Rinnai tankless water heater problem
Moved into a brand new house last January equiped with a natural gas supplied tankless water heater (Rinnai model) which also supplies the radiant heating throughout the house. The vent is a horizontal.No complaints so far either on the hot water supply or with the heating, that is until last week. The warning sensor has now started to go off randomly either when I take a shower or use the diswasher. The error messages are either ''power interruption during bath fill'' or ''flame failure''.... I have to do is a reset, however, this should not be happening. The vent does not seem to be obstructed'. I've read all the info on this sytem but I don't dare taking it apart to investigate the problem since the whole thing is still under warranty by the builder, and they will come and look at it ( after much insistance on my behalf). My question is, (so not to look like a complete idiot when the plumber finally shows up), has anyone experienced this type of problem and what was the probable cause. Because the two error messages seem unrelated to each other this is throwing me off as to what the problem could be. thanks don't worry about looking like an idiot, all the pressure's on the plumber to look knowledgeable. you're the customer, you're supposed to be clueless. do you have a manual? it has a list of error codes and possible causes. the flame failure is a fairly common code and can be caused by quite a few problems. what size is the gas line supplying the unit? it must be 3/4 or larger. when you say the vent is horizontal, does it just run a few feet and terminate on the outside or does it run for quite a distance? if it runs for a longer distance, was a condensation tee and line installed? there are gas pressure adjustments for high and low fire possitions that can cause this problem if they're not in spec. nothing you should be messing with though. if it's under warrantee just have the plumber come out and politely ask if you can watch. these are a fair bit more complicated than the old style heaters and i'm sure you'll learn a few things. my service manuals are in my truck. i'll look at them tommorow and see if i can help you any more. paul
Related Posts:
Thinking of a rheem tankless water heater
Thinking of a Rheem Tankless water heaterWe currently have a 50 Gallon electric water heater and are tired of the huge electric bill. There is a gas access less than a foot away from the water hea...
Tankless water heater replacement
Tankless Water Heater ReplacementI had a 40 gallon gas water heater to heat 4 sinks in a small office building. It was leaking, so I replaced it with a good deal Thermar Gas Tankless Water Heater....
Tankless water heater and btus
Tankless Water Heater and BTUsHello, I would like to replace my heated watertank with a tankless heater. The system is gas. I am trying to figure out how much/min BTUs the new system should have....
Rinnai r75ls tankless heater hot 1 minute cold the next code 10
Rinnai R75LS Tankless Heater - Hot 1 minute, Cold the next (Code 10)Went out to my dad's again over Thanksgiving where he has a Rinnai R75LS, tankless water heater. Over the past two years, the wa...
Whirlpool water heater pilot wont stay lit
whirlpool water heater- pilot won't stay litWe replaced the thermocouple first b/c it wouldn't light at all but the ignitor was working and gas was working. We were able to then get a flame, but i...